Top Page > Product Information > Mass flow meters and Controllers > Thermal Mass Flow ControllersMODEL 5100 SERIES
Mass flow meters and Controllers
- Thermal Mass Flow Controllers
MODEL 5100 SERIES - The high-grade metal sealed mass flow controller products
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES is the top-of-the-line mass flow controller and is the successor to the well-received 3440 SERIES. It is designed as the top-performing industrial-grade gas mass flow controller, with focus on low zero-drift, low range response and good control.

KOFLOC MFC MODEL 5100 SERIES
Quick Review
•Improved Response & Control
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES has improved control/response at all ranges over previous models and improved proportionality to control voltage. It is also equipped with range switching function for multi-range applications. Additional control resolution can be obtained through valve optimization.
•Clean-Room Production
A class 100 clean-room production is available for the KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES, if specified, for applications requiring extra cleanness such as CVD (Chemical Vapor Deposition) and other semiconductor processes.
• KOFLOC Dependability
KOFLOC has 60 years of experience in manufacturing precision flow instruments. KOFLOC products, both standard and off-catalog custom items are well received throughout Japan as the name that manifests confidence. KOFLOC, the fluid expert, is the name professionals trust in precision control of minute flow.
• High Temperature Models
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES has a standard high temperature option especially suited for processes of baking, that can withstand temperature up to 80˚C.
• Diaphragm Valve
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES utilizes the unidirectional normally closed valve with higher dependability and safety. This valve also reduces internal dead-space.
• Standardized Dimensions and Parts
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES retains the standard 3 in (76 mm) footprint, regular fittings and SEMI standard serial connector to easily replace and fit into existing gas lines without any modifications for use in widest possible applications.
• Low Zero Drift
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES looks like any other mass flow controller but it employs the new improved sensor-drive mechanism, improving on the well-regarded zero-drift performance of MODEL 3440 SERIES.
• Adaptability
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES is in wide use as a component CVD, sputter deposition, bond wiring and welding for semiconductor and electronic industries. The MODEL 3200 is also used as a general-purpose mass flow controller in industrial applications of exhaust sampling, including gas mixing, air sampling, burn control and more.
TOP
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES may be used for the following gases.
Medium (gases): Actual gas calibration is available for the gas listed
Air
Argon Ar
Carbon dioxide CO2
Helium He
Hydrogen H2
Nitrogen N2
Oxygen O2
Medium (gases): N2 equivalent conversion factor (CF) is used for the gas listed. Contact KOFLOC for the availability of actual gas calibration.
Acetylene (Ethyne) C2H2
Ammonia NH3
Arsine AsH3
Boron trichloride BCl3
Boron trifluoride BF3
Butadiene (1,3-) C4H6
Butane C4H10
Butene (1-) C4H8
Butene (2-) (Cis) C4H8
Butene (2-) (Trans) C4H8
Carbonylsulfide COS
Carbon monoxide CO
Chlorine Cl2
Cyanogen C2N2
Cyclopropane C3H6
Deuterium D2
Diborane B2H6
Dichlorosilane SiH2Cl2
Dimethylamine C2H6NH
Dimethylether C2H6O
Disilane Si2H6
Ethane C2H6
Ethylene (Ethene) C2H4
Ethylchloride C2H5Cl
Freon-113 C2Cl3F3
Freon-114 C2Cl2F4
Freon-115 C2ClF5
Freon-116 C2F6
Freon-12 CCl2F2
Freon-13 CClF3
Freon-13B1 CBrF3
Freon-14 CF4
Freon-22 CHClF2
Freon-C318 C4F8
Hydrogen bromide HBr
Hydrogen chloride HCl
Hydrogen cyanide HCN
Hydrogen iodide HI
Iso-Butane C4H10
Isobutylene (Isobutene) C4H8
Krypton Kr
Methane CH4
Methylbromide CH3Br
Methylmercaptan CH3SH
Monomethylamine CH3NH2
Neon Ne
Nitric oxide NO
Nitrous oxide N2O
Ozone O3
Pentane C5H12
Phosgene COCl2
Phosphine PH3
Propane C3H8
Propylene (Propene) C3H6
Silane SiH4
Sulfur dioxide SO2
Sulfur hexafluoride SF6
Trimethylamine C3H9N
Xenon Xe
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES may NOT be used for the following gases.
Medium (gases)
Bromine pentafluoride BrF5
Carbon disulfide CS2
Chlorine trifluoride ClF3
Cyanogen chloride ClCN
Dibromo difluoromethane Br2CF2
Ethylene oxide C2H4O
Fluorine F2
Freon-11 CCl3F
Freon-21 CHCl2F
Hydrogen fluoride HF
Hydrogen sulfide H2S
Methylchloride CH3Cl
Nitrogen dioxide NO2
Nitrogen trifluoride NF3
Vinylchloride C2H3Cl
Vinylfluoride C2H3FNote: If you did not find the right gas, please contact KOFLOC for more information.
TOP
•Improved Response & Control
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES has improved control/response at all ranges over previous models and improved proportionality to control voltage. It is also equipped with range switching function for multi-range applications. Additional control resolution can be obtained through valve optimization.
•Clean-Room Production
A class 100 clean-room production is available for the KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES, if specified, for applications requiring extra cleanness such as CVD (Chemical Vapor Deposition) and other semiconductor processes.
• KOFLOC Dependability
KOFLOC has 60 years of experience in manufacturing precision flow instruments. KOFLOC products, both standard and off-catalog custom items are well received throughout Japan as the name that manifests confidence. KOFLOC, the fluid expert, is the name professionals trust in precision control of minute flow.
• High Temperature Models
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES has a standard high temperature option especially suited for processes of baking, that can withstand temperature up to 80˚C.
• Diaphragm Valve
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES utilizes the unidirectional normally closed valve with higher dependability and safety. This valve also reduces internal dead-space.
• Standardized Dimensions and Parts
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES retains the standard 3 in (76 mm) footprint, regular fittings and SEMI standard serial connector to easily replace and fit into existing gas lines without any modifications for use in widest possible applications.
• Low Zero Drift
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES looks like any other mass flow controller but it employs the new improved sensor-drive mechanism, improving on the well-regarded zero-drift performance of MODEL 3440 SERIES.
• Adaptability
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES is in wide use as a component CVD, sputter deposition, bond wiring and welding for semiconductor and electronic industries. The MODEL 3200 is also used as a general-purpose mass flow controller in industrial applications of exhaust sampling, including gas mixing, air sampling, burn control and more.
TOP
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES may be used for the following gases.
Medium (gases): Actual gas calibration is available for the gas listed
Air
Argon Ar
Carbon dioxide CO2
Helium He
Hydrogen H2
Nitrogen N2
Oxygen O2
Medium (gases): N2 equivalent conversion factor (CF) is used for the gas listed. Contact KOFLOC for the availability of actual gas calibration.
Acetylene (Ethyne) C2H2
Ammonia NH3
Arsine AsH3
Boron trichloride BCl3
Boron trifluoride BF3
Butadiene (1,3-) C4H6
Butane C4H10
Butene (1-) C4H8
Butene (2-) (Cis) C4H8
Butene (2-) (Trans) C4H8
Carbonylsulfide COS
Carbon monoxide CO
Chlorine Cl2
Cyanogen C2N2
Cyclopropane C3H6
Deuterium D2
Diborane B2H6
Dichlorosilane SiH2Cl2
Dimethylamine C2H6NH
Dimethylether C2H6O
Disilane Si2H6
Ethane C2H6
Ethylene (Ethene) C2H4
Ethylchloride C2H5Cl
Freon-113 C2Cl3F3
Freon-114 C2Cl2F4
Freon-115 C2ClF5
Freon-116 C2F6
Freon-12 CCl2F2
Freon-13 CClF3
Freon-13B1 CBrF3
Freon-14 CF4
Freon-22 CHClF2
Freon-C318 C4F8
Hydrogen bromide HBr
Hydrogen chloride HCl
Hydrogen cyanide HCN
Hydrogen iodide HI
Iso-Butane C4H10
Isobutylene (Isobutene) C4H8
Krypton Kr
Methane CH4
Methylbromide CH3Br
Methylmercaptan CH3SH
Monomethylamine CH3NH2
Neon Ne
Nitric oxide NO
Nitrous oxide N2O
Ozone O3
Pentane C5H12
Phosgene COCl2
Phosphine PH3
Propane C3H8
Propylene (Propene) C3H6
Silane SiH4
Sulfur dioxide SO2
Sulfur hexafluoride SF6
Trimethylamine C3H9N
Xenon Xe
The KOFLOC High-Grade Metal Sealed Mass Flow Controller MODEL 5100 SERIES may NOT be used for the following gases.
Medium (gases)
Bromine pentafluoride BrF5
Carbon disulfide CS2
Chlorine trifluoride ClF3
Cyanogen chloride ClCN
Dibromo difluoromethane Br2CF2
Ethylene oxide C2H4O
Fluorine F2
Freon-11 CCl3F
Freon-21 CHCl2F
Hydrogen fluoride HF
Hydrogen sulfide H2S
Methylchloride CH3Cl
Nitrogen dioxide NO2
Nitrogen trifluoride NF3
Vinylchloride C2H3Cl
Vinylfluoride C2H3FNote: If you did not find the right gas, please contact KOFLOC for more information.
TOP
Features
Rohs compliance
CE mark
SEMI standard connections
SUS316L stainless steel
Unidirectional normally closed valve
Highly reliable solenoid actuator
Compact
Standard dimensions and fittings for easy replacement
Free mounting position
Wide selection of fittings, seals, wetted materials and communication interfaces
Easy maintenance
TOP
CE mark
SEMI standard connections
SUS316L stainless steel
Unidirectional normally closed valve
Highly reliable solenoid actuator
Compact
Standard dimensions and fittings for easy replacement
Free mounting position
Wide selection of fittings, seals, wetted materials and communication interfaces
Easy maintenance
TOP
Applications
Air sampling
Analyzer component
Bioreactor
Biotechnological process
Burn control
CCFL manufacturing
Chamber pressure control
Chemical process
Environment monitoring
Electronic device manufacturing
Food production
Fuel cell testing
Fermentation process
Gas blending
Gas distribution
Gas flow monitoring
Gas generation
Industrial furnace
Leak testing
Pharmaceutical process
Pollution monitoring
Process flow control
R&D
Solar power element manufacturing
Secondary calibration reference
Semiconductor process
Surface treatment process
Thermal flame spray
Thin film manufacturing
Vapor deposition
TOP
Analyzer component
Bioreactor
Biotechnological process
Burn control
CCFL manufacturing
Chamber pressure control
Chemical process
Environment monitoring
Electronic device manufacturing
Food production
Fuel cell testing
Fermentation process
Gas blending
Gas distribution
Gas flow monitoring
Gas generation
Industrial furnace
Leak testing
Pharmaceutical process
Pollution monitoring
Process flow control
R&D
Solar power element manufacturing
Secondary calibration reference
Semiconductor process
Surface treatment process
Thermal flame spray
Thin film manufacturing
Vapor deposition
TOP
Standard Specifications(5100)
| Flow range | 10 to 5 slm F.S.;10 to 20 slm F.S. |
|---|---|
| Valve type | Diaphragm valve(Normally closed solenoid) |
| Control range | 1.5 sec. or less to within ±2% of full scale of final value typical for 0-100% response |
| Accuracy | Within±1.0%F.S. |
| Linearity | Within±0.5%F.S. |
| Repeatability | Within±0.2%F.S. |
| Working temperature range | 0 to 50°C(Accuracy guarantee:15 to 35°C) |
| Operating differential pressure | F.S.≤5SLM 49kPa~294kPa 5 |
| Proof pressure | 980kPa |
| Materials of parts in contact w/gases | SUS316L,Au or PTFE |
| Joint | Standard;Equivalent to 1/4VCRTMOptional;1/4SWL |
| External leak integrity | 1x10-11Pa.m3/s(He) or less |
| Input signals | 0~5VDC |
| Output singnals | 0~5VDC |
| Power supply | ±15VDC±15%,about 100 mA on positive end and about 200 mA on negative end |
| Mounting position | Available in any position |
Pin Assignment of Dsub 9-pin Connector per KFC Standard
| Pin No. | Signal | Pin No, | Signal |
|---|---|---|---|
| 1 | Input valve operation | 6 | Flow input Hi |
| 2 | Flow output 0-5V | 7 | Flow output COM |
| 3 | +15 VDC Power source | 8 | Flow input Lo |
| 4 | Power source COM | 9 | Output valve voltage |
| 5 | -15 VDC Power source |
* Because a differential input system is used for the product,pin 4(Power source COM)is connected inside the mass flow controller while pin 8(Flow input Lo)is isolated. In case of a single-ended connection,connect pin 8 to pin 4.
* For baking applications on Model 5100B,working temperature is specified up to 80°C.
TOP
* For baking applications on Model 5100B,working temperature is specified up to 80°C.
TOP