Top Page > Product Information > Variable Flow Meter(Rotameter) > High-Grade Flow Meter with Precision Needle Valve MODEL RK1250 SERIES
Variable Flow Meter(Rotameter)
- High-Grade Flow Meter with Precision Needle Valve
MODEL RK1250 SERIES - The high-grade rotameter for use as modular component.
The KOFLOC High-Grade Flow Meter with Precision Needle Valve MODEL RK1250 SERIES is a high-end variable area flow meter, combined with a precision needle valve, with focus on accuracy, ease-of-use and use as a modular component of a larger system.

KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES
Quick Review
•The standard model
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES is the KOFLOC's standard rotameter model,succeeding the previous RK1200 precision flowmeter, coupled with the MODEL 2412 SERIES precision needle valve for fine control of minute flow.
•KOFLOC RK1200 SERIES High Precision Variable Area Flowmeter
KOFLOC RK1200 SERIES High Precision Variable Area Flow Meter is a high-grade rotameter especially suited for measurement and control of minute flow, with an industry reputation of being one of the best analog devices. The new redesigned MODEL RK1250 SERIES retains all the advantages of RK1200 but is more compact.
•KOFLOC 2412 SERIES Precision Needle Valve
KOFLOC 2412 SERIES Non-Rotating Precision Needle valve allows precise and easy flow control of minute amounts of gases and liquids. The internal mechanism converts rotating movement into stable linear movements with minimal vibrations. The needle and orifice has a thermal compensating structure (US P.A.F.) of 0.3%/˚C (15˚C to 35˚C).
•Top/Bottom valve position
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES comes with either the top (outlet) valve or the bottom (inlet) valve. There are many issues to consider in choosing the right valve position. Contact Kofloc for more information.
•KOFLOC Dependability
KOFLOC has 60 years of experiencein manufacturing precision flow instruments. KOFLOC products, both standard and off-catalog custom items are well received throughout Japan as the name that manifests confidence. KOFLOC, the fluid expert, is the name professionals trust in precision control of minute flow.
•Wide flow range coverage
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES comes in 4 sizes of 126, 156, 206 and 256mm that cover small flow ranges from 0.5 ml/min to 3 l/min to medium range of 3 ml/min to 30 l/min.
•Steel/Brass fittings
The fittings are available in either SUS316 stainless steel or brass with respective O-rings of Viton® for SUS316 and NBR for brass fittings.
•Tri-flat & rib-guide flow-tubes
KOFLOC leads the industry in tri-flat flow-tube (for flows between 5 ml/min to 500 ml/min) production with superior precision. The rib-guide flow-tubes are used for medium range flows between 1 l/min and 50 l/min.
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES can only be used for the following gases.
Medium (gases): Actual gas calibration is available for the gas listed
Air, Argon: Ar, Carbon dioxide: CO2, Helium: He, Hydrogen: H2, Nitrogen: N2, Oxygen: O2
N2 equivalent conversion factor (CF) is used for other gases. Contact KOFLOC for the availability of actual gas calibration.
Customization and Optional services
• Optional flow-tubes with ±1% accuracy
• H2O version (for water flows below 1 L/Min) is also available.
TOP
•The standard model
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES is the KOFLOC's standard rotameter model,succeeding the previous RK1200 precision flowmeter, coupled with the MODEL 2412 SERIES precision needle valve for fine control of minute flow.
•KOFLOC RK1200 SERIES High Precision Variable Area Flowmeter
KOFLOC RK1200 SERIES High Precision Variable Area Flow Meter is a high-grade rotameter especially suited for measurement and control of minute flow, with an industry reputation of being one of the best analog devices. The new redesigned MODEL RK1250 SERIES retains all the advantages of RK1200 but is more compact.
•KOFLOC 2412 SERIES Precision Needle Valve
KOFLOC 2412 SERIES Non-Rotating Precision Needle valve allows precise and easy flow control of minute amounts of gases and liquids. The internal mechanism converts rotating movement into stable linear movements with minimal vibrations. The needle and orifice has a thermal compensating structure (US P.A.F.) of 0.3%/˚C (15˚C to 35˚C).
•Top/Bottom valve position
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES comes with either the top (outlet) valve or the bottom (inlet) valve. There are many issues to consider in choosing the right valve position. Contact Kofloc for more information.
•KOFLOC Dependability
KOFLOC has 60 years of experiencein manufacturing precision flow instruments. KOFLOC products, both standard and off-catalog custom items are well received throughout Japan as the name that manifests confidence. KOFLOC, the fluid expert, is the name professionals trust in precision control of minute flow.
•Wide flow range coverage
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES comes in 4 sizes of 126, 156, 206 and 256mm that cover small flow ranges from 0.5 ml/min to 3 l/min to medium range of 3 ml/min to 30 l/min.
•Steel/Brass fittings
The fittings are available in either SUS316 stainless steel or brass with respective O-rings of Viton® for SUS316 and NBR for brass fittings.
•Tri-flat & rib-guide flow-tubes
KOFLOC leads the industry in tri-flat flow-tube (for flows between 5 ml/min to 500 ml/min) production with superior precision. The rib-guide flow-tubes are used for medium range flows between 1 l/min and 50 l/min.
KOFLOC High-Grade Variable Area Flow Meter with Precision Needle Valve MODEL RK1250 SERIES can only be used for the following gases.
Medium (gases): Actual gas calibration is available for the gas listed
Air, Argon: Ar, Carbon dioxide: CO2, Helium: He, Hydrogen: H2, Nitrogen: N2, Oxygen: O2
N2 equivalent conversion factor (CF) is used for other gases. Contact KOFLOC for the availability of actual gas calibration.
Customization and Optional services
• Optional flow-tubes with ±1% accuracy
• H2O version (for water flows below 1 L/Min) is also available.
TOP
Features
♦ The Standard Kofloc variable area flow meter
♦ Fine control of minute flow
♦ Precision needle valve
♦ Numerous variants and custom models
♦ All new design
TOP
♦ Fine control of minute flow
♦ Precision needle valve
♦ Numerous variants and custom models
♦ All new design
TOP
Applications
♦ Use as a modular component
♦ Use with gas equipment in semiconductor industry
♦ Bio-Industry
♦ Vacuum line control
♦ General industrial applications
♦ Pre-processing stage
♦ Collector and sampler
♦ Electric furnace
♦ CCFL
♦ Washer and dryer
♦ Flow control
♦ Asbestos collector
TOP
♦ Use with gas equipment in semiconductor industry
♦ Bio-Industry
♦ Vacuum line control
♦ General industrial applications
♦ Pre-processing stage
♦ Collector and sampler
♦ Electric furnace
♦ CCFL
♦ Washer and dryer
♦ Flow control
♦ Asbestos collector
TOP
Standard Specifications
| Gases | Liquids | |
|---|---|---|
| Fluids | Air,N2,O2,H2,He,Ar,and CO2 (Calibration by actual gas) For other gases,consultation is necessary regarding whether conversion conditions or calibration by actual gas is to be used. *Optional:Scale indicating two types of fluids | Standard fluie:Water For other liquids,consultation is necessary regarding whether conversion conditions or calibration by actual liquid is to be used. |
| Flow range | 0.5-5ml/min to3-30l/min (See the Capacity Table below.)*Optional:0.5-3ml/min | 0.5-5ml/min to 0.1-1l/min (See the Capacity Table below.)*Optional:0.5-3ml/min |
| Accuracy | FS±2%(Measurement point) *Optional:FS±1%(Measurement point) | FS±2%(Measurement point) |
| Proof pressure | 1.0MPa for 100ml/min or less 0.7MPa for 5 l/min or less 0.5MPa for 10 l/min or more | 1.0MPa for 100ml/min or less 0.5MPa for 300 ml/min or more |
| Available scale | 10:1 *Optional:20:1 | |
| Materials | SS | BS |
| Body block | SUS316 | Brass |
| Tapered tube | Pyrex | |
| Packing | Viton | NBR |
| Float | Pyrex,SUS316 | |
| Protective cover | Acrylic resin | |
| Heat resistance | 120°C | 70°C |
| Connection end | Rc1/4(Standard);Rc1/8(Optional) | |
Capacity Table
| Air(Flow rate at atmospheric pressure) ML/MIN,L/MIN | |||||||||
| mm | 5ML | 10ML | 20ML | 30ML | 50ML | 100ML | 150ML | 200ML | 300ML |
|---|---|---|---|---|---|---|---|---|---|
| 126 | O | O | O | O | O | O | O | O | O |
| 156 | - | O | O | O | O | O | O | O | O |
| 206 | - | - | - | - | O | O | O | O | O |
| 256 | - | - | - | - | - | O | O | O | O |
| mm | 500ML | 1L | 2L | 3L | 5L | 10L | 15L | 20L | 30L |
| 126 | O | O | O | O | O | O | O | O | O |
| 156 | O | O | O | O | O | O | O | O | O |
| 206 | O | O | O | O | O | O | O | O | O |
| 256 | O | O | O | O | O | O | O | O | O |
| H2O ML/MIN,L/MIN | |||||||||
| mm | 5ML | 10ML | 20ML | 30ML | 50ML | 100ML | 150ML | 200ML | 300ML |
| 126 | O | O | O | O | O | O | O | O | O |
| 156 | O | O | O | O | O | O | O | O | O |
| 206 | O | O | O | O | O | O | O | O | O |
| 256 | O | O | O | O | O | O | O | O | O |
| mm | 500ML | 1L | |||||||
| 126 | O | O | |||||||
| 156 | O | O | |||||||
| 206 | O | O | |||||||
| 256 | O | O | |||||||